BOARD
ID="GCI0001" ; ISA Gateway Ethernet AT Interface Card Rev 01
NAME="G/Ethernet AT" ; Product Name
MFR="Gateway Comm., Inc." ; Manufacturer's Name
CATEGORY="NET" ; Category = Network Board
SLOT=ISA16 ; Uses ISA 16 Bit Slot
LENGTH=170 ; Length of board in Millimeters
READID=YES ; Board ID can be read
;
COMMENTS="Gateway Communications' G/Ethernet 16 bit AT Adapter\n
If configuring the card for use with NetWare(r),\n
the IRQ lines and I/O port addresses ARE linked.\n
See the installation manual for details.\n\n
Remote Boot is automatically initiated if...\n
there is no disk drive, and, a BOOTROM is in its socket."
;
SWITCH(1)=8 ; 8 position switch
NAME="SW1: IO Adr/BOOTROM" ; Switch sets board I/O address and Remote
; Boot ROM memory address
STYPE=DIP ; type = DIP Switch
VERTICAL=NO ; Switch is positioned horizionally
REVERSE=YES ; Switch positions number 1 - 8
LABEL=LOC(1-8)"SW1-1""SW1-2""SW1-3""SW1-4""SW1-5""SW1-6""SW1-7""SW1-8"
INITVAL=LOC(7-8)00 ; Switches 7 & 8 are not used & set to OFF
FACTORY=LOC(1-8)10110000 ; Factory default setting = I/O 2a0
COMMENTS="\t Default I/O port address is 2A0h; that is,\n
\t switches 1, 3, & 4 ON, the rest OFF.\n
\t Default BOOTROM address is 0CC0000; that is\n
\t switches 5 $ 6 OFF\n
\t Remote Boot is automatically initiated\n
\t if... there is no disk drive, and, a\n
\t BOOTROM is in its socket.\n
\t Switches 7 & 8 must be OFF.\n
\t "
;
JUMPER(1)=10 ; 10 position jumper
NAME="JP2: IRQ selection" ; Jumper JP2 sets board interrupt number
JTYPE=PAIRED ; Standard Berg type DIP header
VERTICAL=YES ; Jumper block is positioned vertically
REVERSE=NO ; Positions do not number from top to bottom
LABEL=LOC(1-5)"IRQ2""IRQ7""IRQ6""IRQ5""IRQ4"
LABEL=LOC(6-10)"IRQ3""IRQ10""IRQ11""IRQ12""IRQ15"
FACTORY=LOC(6)1 ; default = IRQ3
COMMENTS="\t Only 1 jumper may be set at one time.\n
\t Default is IRQ3; that is, jumper loc. 2.\n
\t "
;
JUMPER(2)=4 ; 4 position jumper
NAME="JP4: Cable Type" ; selects Thick or Thin Ethernet
JTYPE=TRIPOLE ; Standart Berg type Tripole Header
VERTICAL=NO ; Header is positioned horizontally
REVERSE=YES ; Numbers from left to right
FACTORY=LOC(1-4)1111 ; Factory default selscts Thin Ethernet
COMMENTS="\t Thin-wire is default, use BNC connector.\n
\t All 4 jumpers must be UP.\n
\t Thick-wire, use AUI connector.\n
\t All 4 jumpers must be DOWN.\n
\t "
HELP="\t Thin-wire is default, use BNC connector.\n
\t All 4 jumpers must be UP.\n
\t Thick-wire, use AUI connector.\n
\t All 4 jumpers must be DOWN."
;
FUNCTION="G/Ethernet Adapter for AT bus."
CHOICE="G/Ethernet 16 bit AT Adapter"
LINK
IRQ=3|2|7|6|5|4|10|11|12|15
INIT=JUMPER(1)LOC(1-10)
0000010000|1000000000|0100000000|0010000000|0001000000|
0000100000|0000001000|0000000100|0000000010|0000000001
;
LINK
PORT=2A0h-2BFh|280h-29Fh|2C0h-2DFh|2E0h-2FFh|300h-31Fh|
320h-33Fh|340h-35Fh|360h-37Fh
INIT=SWITCH(1)LOC(1-4)
1011|1111|1101|1001|1110|1010|1100|1000
;
FUNCTION="Ether Thin/Thick Cable Type"
COMMENTS="\t Thin/Thick Cable Selection:\n
\t Thin-cable is default, use BNC connector.\n
\t All 4 jumpers must be UP.\n
\t Thick-cable, use AUI connector.\n
\t All 4 jumpers must be DOWN.\n
\t "
HELP="\t Thin-wire is default, use BNC connector.\n
\t All 4 jumpers must be UP.\n
\t Thick-wire, use AUI connector.\n
\t All 4 jumpers must be DOWN."
CHOICE="Thin-Wire (BNC) Connection"
FREE
INIT=JUMPER(2)LOC(1-4)1111
CHOICE="Thick-Wire (AUI) Connection"
FREE
INIT=JUMPER(2)LOC(1-4)0000
;
FUNCTION="Remote BOOTROM Address"
COMMENTS="\t Remote Boot is automatically initiated\n
\t if... there is no disk drive, and, a\n
\t BOOTROM is in its socket.\n
\t "
CHOICE="BOOTROM Address"
LINK
MEMORY=16K
ADDRESS=0CC000h|0C0000h|0C4000h|0C8000h
WRITABLE=NO
MEMTYPE=OTHER
INIT=SWITCH(1)LOC(5-6)00|11|01|10
;
; End of board